Item | Specification |
Cabinet installation standards | The chassis can be installed in a 19-inch standard cabinet with a depth of 1000 mm at least. A 1200 mm deep cabinet is recommended. For details about the cabinet requirements, see Hardware Installation and Maintenance > Preparation Before Installation > Checking the Cabinet. |
Dimensions without packaging (H x W x D) [mm(in.)] | 438 mm x 442 mm x 874 mm (17.24 in. x 17.40 in. x 34.41 in.) (dimensions of the chassis body)438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including the chassis front and rear decorating parts and cable tray) |
Dimensions with packaging (H x W x D) [mm(in.)] | 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.) |
Chassis height [U] | 9.8U |
Weight without packaging [kg(lb)] | 78.1 kg (172.18 lb) |
Weight with packaging [kg(lb)] | 142 kg (313.05 lb) |
Weight without packaging (full configuration) [kg(lb)] | 19.2T bundle: 229.1 kg (505.07 lb) (fully configured with 19.2T LPUs) NOTE: The weight of a device can be estimated based on the board configuration using Info-Finder Hardware Configuration. |
Typical power consumption (with configuration) [W] | 5296 W (fully loaded with LPUF-6T4s, with each LPUF-6T4 having two 8x400G subcards, 9.6T bundle) 8964 W (fully loaded with LPUI-19T2s, 19.2T bundle) NOTE: The power consumption of a device can be estimated based on the board configuration using Info-Finder Hardware Configuration. |
Typical heat dissipation (with configuration) [BTU/hour] | 13594.8BTU/hour (fully loaded with LPUF-6T4s, with each LPUF-6T4 having two 8x400G subcards, 9.6T bundle) 23010.6 BTU/hour (fully loaded with LPUI-19T2s, 19.2T bundle) |
MTBF [year] | 23.8 year |
MTTR [hour] | 0.5 hour |
Availability | 0.99999 |
Power supply mode | DC |
Maximum number of power chassis inputs | (12 channels/PEM) x 1 PEM = (2 channels/PM) x 6 PMs = 12 channels |
Rated input voltage [V] | –48/–60 V |
Input voltage range [V] | –40 V to –72 V |
Maximum input current [A] | 2200 W DC PM: 58.5 A/PM 3000 W DC PM: 82 A/PM 4000 W DC PM: 113 A/PM |
Maximum input cable size [mm²] | 35 mm² |
Front-end circuit breaker/fuse [A] | 2200 W DC PM: 2 x 63 A per PM, 6 PMs, up to 12 x 63 A for the entire chassis 3000 W DC PM: 2 x 100 A per PM, 6 PMs, up to 12 x 100 A for the entire chassis 4000 W DC PM: 2 x 125 A per PM, 6 PMs, up to 12 x 125 A for the entire chassis NOTE: Ensure that the upstream circuit breaker connects to the power supply in one-to-one mode. Do not connect one circuit breaker to multiple power supplies at the same time. |
Heat dissipation mode | air cooling |
Airflow direction | Front-to-back airflow |
Noise at normal temperature (acoustic power) [dB(A)] | < 78 dB(A) @ 27°C |
Number of slots | 14 |
Number of service board slots | 4 |
Switching capacity | 64.93 Tbit/s (6.4T bundle) 86.57 Tbit/s (9.6T bundle) 173.15 Tbit/s (19.2T bundle) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 7+1 |
Redundant power supply | 5+1 |
Redundant fans | Supports redundancy backup of a single fan. |
Long-term operating temperature [°C(°F)] | 0°C to 40°C (32°F to 104°F) |
Short-term operating temperature [°C(°F)] | –5°C to +50°C (23°F to 122°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Storage environment | ETSI EN 300 019-1-1 Class 1.2 NOTE: The product has a valid storage period of one year.The valid storage period refers to the period during which the product maintains the required quality when stored in an environment that meets the preceding requirements. |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by 1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.) |
Storage altitude [m(ft.)] | < 5000 m (< 16404.2 ft.) |
Number of slots | 26 |
Number of service board slots | 16 |
Switching capacity | 43.29 Tbit/s (1T bundle) |
86.57 Tbit/s (2T bundle) | |
129.86 Tbit/s (3.2T bundle) | |
259.72 Tbit/s (6.4T bundle) | |
346.30 Tbit/s (9.6T bundle) | |
692.60 Tbit/s (19.2T bundle) | |
Redundant MPUs | 1:01 |