| Customization: | Available |
|---|---|
| Type: | Wired |
| Network Site: | Wide Area Router |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




Item | Specification |
Cabinet installation standards | The chassis can be installed in a 19-inch standard single-door cabinet with a depth of 1000 mm at least. For details about the cabinet requirements, see Hardware Installation and Maintenance > Preparation Before Installation > Checking the Cabinet. |
Dimensions without packaging (H x W x D) [mm(in.)] | 86.1 mm x 442 mm x 600 mm (3.39 in. x 17.40 in. x 23.62 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 280 mm x 660 mm x 875 mm (11.02 in. x 25.98 in. x 34.45 in.) |
Chassis height [U] | 2 U |
Weight without packaging [kg(lb)] | 20.1 kg (44.31 lb) |
Weight with packaging [kg(lb)] | 28.3 kg (62.39 lb) |
Weight without packaging (full configuration) [kg(lb)] | DC: 23.7 kg (52.25 lb) AC: 22.9 kg (50.49 lb) |
Weight with packaging (full configuration) [kg(lb)] | DC: 34.2 kg (75.4 lb) AC: 32.1 kg (70.77 lb) |
Typical power consumption (with configuration) [W] | 1153.2 W |
Typical heat dissipation (with configuration) [BTU/hour] | 3526.75 BTU/hour |
MTBF [year] | DC: 21.90 AC: 22.03 |
MTTR [hour] | 0.5 hour |
Availability | 0.99999 |
CPU | 24-core 2.2 GHz |
Memory | 32 GB |
Flash memory | 64 MB |
Storage | 16 GB |
Power supply mode | DCAC/HVDC |
Maximum number of power chassis inputs | 2 |
Rated input voltage [V] | DC: –48 V to –60 V AC: 100 V to 130 V (dual-live wire)/200 V to 240 V HVDC: 190 V–240 V |
Input voltage range [V] | DC: –40 V to –72 V AC: 90 V–290 V HVDC: 190 V–290 V |
Maximum input current [A] | DC: 63 A AC/HVDC: 16 A |
Rated output power [W] | DC: 3000 W AC: 3000 W (input: 200 V AC to 290 V AC/200 V DC to 290 V DC) 2800 W (input: 176 V AC to 200 V AC/190 V DC to 200 V DC) |
Maximum input cable size [mm²] | DC: 25 mm² AC/HVDC: 2.5 mm² |
Front-end circuit breaker/fuse [A] | DC: ≥ 63 A AC: ≥ 16 A |
Types of fans | Pluggable |
Heat dissipation mode | Air cooling |
Airflow direction | Front-to-rear airflow model: port-side air intake |
Noise at normal temperature (acoustic power) [dB(A)] | < 78 dBA |
Number of slots | 6 |
Number of service board slots | 1 |
Switching capacity | 14.4 Tbit/s |
Maximum number of physical ports on the entire device | 72 |
Maximum number of 400GE ports | 16 |
Maximum number of 100GE ports | 72 |
Maximum number of 50GE ports | 72 |
Maximum number of 40GE ports | 72 |
Redundant power supply | 1+1 |
Redundant fans | N+1 redundancy. The system can work at 40°C (104°F) for a short period of time after a single fan rotor fails. |
Long-term operating temperature [°C(°F)] | Front-to-rear airflow model: –5°C to +45°C (23°F to 113°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Storage environment | ETSI EN 300 019-1-1 Class 1.2 NOTE: The product has a valid storage period of one year.The valid storage period refers to the period during which the product maintains the required quality when stored in an environment that meets the preceding requirements. |
Long-term operating relative humidity [RH] | 5% RH to 90% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m |
Breakout supported | Yes Ports 0 to 71 support 4x25G breakout and 4x10G breakout. |