| Customization: | Available |
|---|---|
| Type: | Wired |
| Network Site: | Wide Area Router |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency




Item | Specification |
Cabinet installation standards | The chassis can be installed in a 19-inch standard single-door cabinet with a depth of 600 mm at least. For details about the cabinet requirements, see Hardware Installation and Maintenance > Preparation Before Installation > Checking the Cabinet. |
Dimensions without packaging (H x W x D) [mm(in.)] | 575 mm x 442 mm x 482.8 mm (22.64 in. x 17.40 in. x 19.01 in.) (dimensions of the chassis body, excluding mounting brackets) 575 mm x 482.6 mm x 585 mm (22.64 in. x 19.00 in. x 23.03 in.) (including mounting brackets and cable management frames) |
Dimensions with packaging (H x W x D) [mm(in.)] | 835 mm x 765 mm x 725 mm (32.87 in. x 30.12 in. x 28.54 in.) |
Chassis height [U] | 13 U |
Weight without packaging [kg(lb)] | 55 kg (121.25 lb) |
Weight with packaging [kg(lb)] | 87 kg (191.80 lb) |
Weight without packaging (full configuration) [kg(lb)] | 1.6T/2T bundle: 120.5 kg (265.7 lb) 6.4T bundle: 121.6 kg (268.1 lb) NOTE: The weight of a device can be estimated based on the board configuration using Info-Finder Hardware Configuration. |
Weight with packaging (full configuration) [kg(lb)] | 1.6T/2T bundle: 152.8 kg (336.9 lb) 6.4T bundle: 154.2 kg (339.95 lb) |
Typical power consumption (with configuration) [W] | 1.6T/2T bundle: 1680.1 W (configured with eight LPUTs and twenty 10x10GE ports and eight 10xGE ports) 6.4T bundle: 2362 W (configured with SRU 6T4-B and four 8x100GE ports and four 72x10GE ports) NOTE: The power consumption of a device can be estimated based on the board configuration using Info-Finder Hardware Configuration. |
Typical heat dissipation (with configuration) [BTU/hour] | 1.6T/2T bundle: 5262.6 BTU/hour (configured with eight LPUTs and twenty 10x10GE ports and eight 10xGE ports) 6.4T bundle: 7558.1 BTU/hour (configured with four 8x100GE ports and four 72x10GE ports) NOTE: The heat dissipation of a device can be estimated based on the board configuration using Info-Finder Hardware Configuration. |
MTBF [year] | 38.41 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999998514 |
Power supply mode | DCAC/HVDC |
Maximum number of power chassis inputs | DC: (2 channels/PM) x 6 PMs = 12 channels AC/HVDC: (1 channel/PM) x 6 PMs = 6 channels |
Rated input voltage [V] | DC: –48 V/–60 V AC: 100 V to 130 V dual-live wire/200 V to 240 V, 50/60 Hz HVDC: 240 V |
Input voltage range [V] | DC: –40 V to –72 V AC: 90 V to 290 V HVDC: 190 V to 290 V |
Maximum input current [A] | DC: 63 A/PM AC: 16 A/PM HVDC: 14 A/PM |
Maximum input cable size [mm²] | DC: 25 mm² AC/HVDC: 2.5 mm² |
Heat dissipation mode | air cooling |
Airflow direction | Front-to-back airflow + left-to-back airflow |
Noise at normal temperature (acoustic power) [dB(A)] | < 78 dB(A) @ 27°C |
Number of slots | 12 |
Number of service board slots | 8 |
Switching capacity | 1.6 bundle: 11.35 Tbit/s 2T bundle: 11.35 Tbit/s 6.4T bundle: 28.86 Tbit/s |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 1:1 |
Redundant power supply | DC: [1.6T/2T bundle] 2+1, [6.4T bundle] 2+1 AC: [1.6T/2T bundle] 1+1, [6.4T bundle] 2+2 |
Redundant fans | Two fan trays are configured by default. The system can work at 40°C (104°F) for a short term when a fan fails. |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | –5°C to +55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Storage environment | ETSI EN 300 019-1-1 Class 1.2 NOTE: The product has a valid storage period of one year.The valid storage period refers to the period during which the product maintains the required quality when stored in an environment that meets the preceding requirements. |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.36 ft.) (From 1800 m to 4000 m [5905.51 ft. to 13123.36 ft.], the operating temperature of the device decreases by 1°C [1.8°F] for every 220 m [721.78 ft.] increase in altitude.) |
Storage altitude [m(ft.)] | < 5000 m (< 16404.2 ft.) |